Get a Quote | Subscribe to MFC E-Mails |
Specifications: | |
---|---|
Cut-Off Frequency Option: | 50 – 500 MHz (see chart below) |
Passband Insertion Loss: |
0.5 dB Max |
Passband Return Loss: |
16 dB Min |
Passband Power (CW): | 100 Watts Max |
Rejection: | 50 dB Min from 1.3(Fc) to 6.0(Fc) |
Operating Temperature Range: |
-20º C to +70º C |
Impedance: | 50 ohms |
Connectors: | N-female |
Model |
Frequency (Fc) MHz |
19141-50 |
50 |
19141-100 |
100 |
19141-150 |
150 |
19141-200 |
200 |
19141-250 |
250 |
19141-300 |
300 |
19141-350 |
350 |
19141-400 |
400 |
19141-450 |
450 |
19141-500 |
500 |